The FMP-825 fluorescence microplate reader can be used with the FP-8300 or FP-8500. Four standard measurements are available including Spectra Measurement, Quantitative Analysis, Time Course, and Fixed Wavelength. Quantitative Analysis can be used to create a calibration curve, as well as measure unknown samples in a single microplate while the Time Course Measurement software can be used to measure parallel kinetics for multiple samples.
Specifications | |
---|---|
Compatible plates | 96 and 384 well microplate (SBS standard) |
Measurement time | 1 min/ per plate (96 wells fixed wavelength under specified conditions) |
Minimum sample requirement | 80uL per well (96 well plate) |
Photometric Reproducibility | +/- 3% |
Optional Accessories | Constant temperature plate holder |
Temperature Control | Heating system |
Temperature Control Range | RT + 10 to 50 deg C |
The autosampler system obtains automated measurement by combining an autosampler, syringe pump or sipper, and flow cell unit. Up to 192 liquid samples can be measured on all FP-8000 models and there are various rack options that can be used with either test tubes and/or vials. The system allows for automated scanning measurements at predetermined parameters using a flow cell. The PC control Spectra Managerâ„¢ software is included as standard.
Rack Type | Compatible test tube and vials | Max. Samples |
---|---|---|
SRA-811 15 mm OD test tube | 15 mm OD x 105 mm L 10 mL 100 pcs/set | 100 |
SRA-812 13 mm OD test tube | 13 mm OD x 100 mm L 7 mL 100 pcs/set | 100 |
SRA-813 12 mm OD test tube | 12 mm OD x 105 mm L 5 mL 100 pcs/set | 150 |
SRA-814 10 mm OD test tube | 10 mm OD x 90 mm L 3 mL 100 pcs/set | 150 |
SRA-818 Vial | Screw cap vial 2mL 500 pcs/set | 120 |
SRA-816 Microplate | 96 well microplate, 250uL | 192 |
SRA-817 Constant temperature microplate | 96 well amplification, plate 250uL | 192 |
Automatically transfers small sample aliquots to autosampler tray. The ASP-849 can be used with syringe volumes of 1.0. 2.5, 5.0, and 10.0 mL and has a reproducible volume delivery within ±1%.
Samples are automatically aspirated, transferred directly from the sample vessel into instrument, measured, and drained. More viscous samples can be easily transferred and up to 450 samples can be measured per hour.
Samples are automatically aspirated, transferred directly from the sample vessel into instrument, measured, and drained. Sample can be recollected and up to 360 samples can be measured per hour.
Optional washing unit for use with QFS-821/822 and SHP-819/820.