Model | Type |
---|---|
UCB-710 | Rectangular cell holder |
LSE-701 | Long path cell holder |
FSE-702 | 4-position long path cell holder |
SSE-704 | 6-position manual cell holder |
NCP-705 | 6-position automatic cell changer |
CYH-708 | Cyrindrical cell holder |
EMC-709 | 5 µL Ultra-micro cell holder |
TCH-703 | 8-position micro turret cell holder |
Model | Type |
---|---|
STR-773 | Water thermostatted cell holder with stirrer |
HMC-711 | Water thermosttated micro cell holder (100 µL, 200 µL) |
MHT-745 | Manual 4-position water thermostatted turret cell holder |
NCP-706 | Water thermostatted 6-position automatic cell changer |
EHC-716 | Peltier thermostatted single cell holder (air-cooled) |
Model | Type |
---|---|
ETC-717 | Peltier thermostatted single cell holder (water-cooled) |
PSC-718 | Automatic 6-position Pelier cell changer (air-cooled) |
PWC-758 | Automatic 8-position Pelier cell changer (water-cooled) |
OPS-512 | Optional temperature sensor for ETC-716 and EHC-717 |
OPS-513 | Optional temperature sensor for PSC-718 |
PAC-743 | Automatic 6/8-position Peltier Cell Changer (water-cooled) |
PAC-743R | Automatic 6/8-position Peltier Cell Changer (water-cooled, thermostatted reference) |
Suitable for cuvettes sizes down to 2 mm width x variable path length up to 10 mm (minimum sample volume of 240 µL)
1.5 mm (W) x 3 mm (H) mask included as standard
Used for sample measurements using long light path rectangular cells (maximum: 100 mm). Typical pathlengths include 10 mm, 20 mm, 50 mm or 100 mm. A cell of the same pathlength can also be placed on the reference side.
Ideal for sample measurements using long path rectangular cells (maximum: 100 mm). Typical path lengths include 10 mm, 20 mm, 50 mm or 100 mm. A cell of the same pathlength can also be used for the reference side.
SSE-704 6-position manual cell holder for up to 6 sample cell positions. The cell changer is manually operated and can be used with cell sizes of 5 mm, 10 mm or 20 mm. A cell of the same pathlength can also be used for the reference side.
The NCP-705 and NCP-706 6-position automatic cell changers for up to 6 sample positions. The sample position can be selected using software control and can be used with cell path lengths up to 10 mm. A single cell is used for the reference position for both the NCP-705/706 automatic six cell changers.
The NCP-706 includes temperature control using a water-thermostatted circulator.
CYH-708 cylindrical cell holder for sample measurement using cylindrical cells (Diameter: 22 or 30 mm; maximum path length: 100 mm)
Sample movement | Linear |
Cell type | 10-mm rectangular cell, Micro Cell (min. sample width 2 mm) |
Reference cell holder | Single-cell holder |
Dimensions | 130 (W) x 255 (D) x 123 (H) mm |
Weight | 2.0 kg |
Sample movement | Linear |
Cell type | 10-mm rectangular cell, Micro Cell (min. sample width 2 mm) |
Thermostatic method | Circulation of constant temperature water |
Operating temperature | Room temperature plus 10° -90°C |
Reference cell holder | Constant temperature single-cell holder |
Dimensions | 130 (W) x 255 (D) x 123 (H) mm |
Weight | 2.5 kg |